REV PCN DATE
03 - 28-MAR-12
IMPORTANT SAFETY INFORMATION: Always read this manual rst before attempting to service
this stove. For your safety, always comply with all warnings and safety instructions contained in this
manual to prevent personal injury or property damage.
Vista de página 0
1 2 3 4 5 6 ... 10 11

Resumo do Conteúdo

Página 1 - Service Manual

Service ManualModel Number DS2205DS2307DS3311DS44117400570000R03In keeping with our policy of continuous product development, we reserve the right to

Página 2 - TABLE OF CONTENTS

10 www.dimplex.comPROBLEM CAUSE SOLUTIONGeneralCircuit breaker trips or fuse blows when unit is turned onShort in unit wiring

Página 3 - OPERATION

11PROBLEM CAUSE SOLUTIONHeaterHeater is not turning off Improper operation Refer to Operation SectionDefective Heater On/Off Switch Replace Heater On/

Página 4 - MAINTENANCE

2 www.dimplex.comAlways use a qualied technician or service agency to repair this stove.! NOTE: Procedures and techniques t

Página 5 - EXPLODED PARTS DIAGRAM

3Low Heat SwitchThe Low Heat Switch supplies power to the heater fan and the heater element. When the switch is in the On position the heater operate

Página 6 - WIRING DIAGRAM

4 www.dimplex.comMAINTENANCE WARNING: Disconnect power before attempting any maintenance or cleaning to reduce the risk of 

Página 7

5EXPLODED PARTS DIAGRAM61234591087131211141516181720201. Front FootDS2205 DS2307 DS3311 DS44110438460160RP2. Rear Foot N/A 0438460160RP N/A3. Logset A

Página 8 - Thermostat

6 www.dimplex.comWIRING DIAGRAMSwitchLampFlicker MotorCordBlowerMotorElement CutoutLampTerminalBlockThermostatWide blade (N)W

Página 9 - Power Cord Replacement

7With Three Switch Control (No Remote)SwitchSwitchSwitchLampFlicker MotorCapacitorBlowerMotorElement BankCutoutLampTerminalBlock

Página 10 - TROUBLESHOOTING GUIDE

8 www.dimplex.comSwitch Replacement - Units with Thermostat WARNING: If the stove was operating prior to servic-ing, allow

Página 11 - PROBLEM CAUSE SOLUTION

9Flicker Motor/Flicker Rod Replacement WARNING: If the stove was operating prior to servic-ing, allow at least 10 minutes for light bulbs and heatin