Specifications
Voltage 208, 240, 480V
Wattage Nine sizes ranging from 3 to 35kW
Finish Polyester powder coated paint.
Construction Heavy-duty constructed for hostile environments, the housing has a
14 gauge steel cabinet. Adjustable louvers provide directional control
of airflow.
Heating The heater is constructed of rugged, seamless copper-sheathed tubular
Element elements. The low watt density allows for long heater and fluid life.
Heat The advanced design allows lower operating temperatures
Exchanger from sealed liquid-to-air heat exchanger with steel tubes, and integral
aluminum fins. The pressure relief device provides excess pressure
protection.
Motor & The explosion-proof, ball bearing motor is permanently lubricated
Fan and has built-in thermal overload protection. Both fan and motor are
protected by a heavy duty grill. The epoxy coated, aluminum fan blade
prevents any possibility of sparking.
Controls Standard 120V control circuit with magnetic contactor and transformer.
A terminal connection is provided for an external 120V thermostat
circuit. Optional controls include built-in adjustable thermostat,
built-in disconnect switch.
Warranty One year on complete unit. CUL/UL approved.
Features
• Low surface temperature
heat exchanger
• Spark-free, dynamically and
statically balanced fan
• Choice of wall, ceiling or
pole mounting
• Safe, long-life propylene
glycol heat transfer fluid
• Can be serviced without
dismounting unit
Applications
• Sewage treatment plants,
petrochemical facilities
& oil refineries, chemical
storage & handling facilities,
paint storage areas, aircraft
servicing areas & areas
containing metal dust
32 | INDUSTRIAL HEATERS TO ORDER PLEASE CALL 1-800-668-6663 OR FAX 1-800-668-6665
Designed for areas classified as hazardous locations
to provide primary or supplemental heating,
or freeze protection.
Hazardous Location Unit Heater
CXH-EP Series
Classifications
Class 1, Divisions 1 and 2, Group D
Class 2, Division 1, Groups E, F and G
Class 2, Division 2, Groups F and G
Units are rated for National Electric Code
Temperature Code T3B, 165 F (329F) CSA and
UL Approved.
Comentários a estes Manuais