Service Manual23” Compact FireplaceModel Number:DF2305DF2307SSDFB4047DFB2306DFS2308UL Part Number69017400007400080000R03In keeping with our policy of
10 www.dimplex.comPROBLEM CAUSE SOLUTIONGeneralCircuit breaker trips or fuse blows when unit is turned onShort in unit wiring. Trace wirin
11PROBLEM CAUSE SOLUTIONHeaterHeater is not turning off Improper operation Refer to Operation SectionDefective Heater Switch Replace Heater SwitchDefe
2 www.dimplex.comAlways use a qualied technician or service agency to repair this replace.! NOTE: Procedures and techniques that are c
3Remote ControlThe replace is supplied with a radio frequency remote control. This remote control has a range of approximately 50 feet (15.25 m), it
4 www.dimplex.com MAINTENANCE WARNING: Disconnect power before attempting any maintenance or cleaning to reduce the risk of re, electric
5EXPLODED PARTS DIAGRAM6182345221013712151111614REPLACEMENT PARTS1. Log Set Assembly ...10438200700RP2. Flicker Motor ...
6 www.dimplex.comWIRING DIAGRAM MOD A & B (Integral Remote)MOD 0 - No Remote
7LIGHT HARNESS REPLACEMENTTools Required: Phillips Head Screwdriver CAUTION: If unit was operating prior to servicing allow at least 10 minutes for
8 www.dimplex.com! NOTE: A at head screwdriver can be used to gently pry between the end of the connector and the switch to release the
9at least 10 minutes for lights, heating elements and top panel to cool off to avoid accidental burning of skin. WARNING: Disconnect power before at