Dimplex LPP050 Instruções de Operação Página 32

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 104
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 31
Dimplex Heatbook
Control
requirement Model
Signalling
method
Product features Compatibility
24 hour control
over one heater
Programmable
24 hour digital timer
RX24TI and RX24TIB
Single
heater
Programmable 24 hour time control; panel heater can be configured to its own individual operating programme.
Plugs directly into panel heater
4 programmable time periods, switching heater between on/off modes
Programme advance and manual override features
1 timer required per heater Cassette can be removed from heater for easy programming
Back lit LCD with powersave mode Programmes saved in memory for 12 hours in event of power failure
Quick start user guides printed on rear of programming cassette
Available in white (RX24TI) or black (RX24TIB)
Monterey, Girona,
Saletto and EPX
Runback timer for
one heater
Electronic
runback timer
RXRBTI and
RXRBTIB
Single
heater
Allows the heater to operate only for a preset period of time each time the controller is activated.
Runback timer cassette – plugs directly into panel heater
Installer adjustable runback time, 30 mins to 4 hours (in 30 min increments)
Switches heater between on and off modes on button press 1 timer required per heater
Can be locked into heater by installer, preventing user from tampering with time settings
Neon indicates when time period is active
Alternative ‘advanced’ mode allows heater to be controlled on comfort/background basis
Available in white (RX24TI) or black (RX24TIB)
Monterey, Girona,
Saletto and EPX
7 day control over
multiple heaters
Single zone
programming cassette
RXPW1
Pilot wire Allows multiple panel heaters to be controlled on a common time programme, with slave heaters linked to
a master heater via pilot wire.
7 day, single zone pilot wire programming cassette – plugs directly into heater
Master/slave control – master heater fitted with programmer controls up to 10 slave heaters via pilot wire
4 programmable time periods for weekdays and weekends, switching heater between on/off modes
Programme advance and manual override features Cassette can be removed from heater for easy programming
Back lit LCD with power-save mode Programmes saved in memory for 12 hours in event of power failure
Quick start user guides printed on rear of programming cassette
Monterey, Girona,
Saletto and EPX
7 day control over
multiple heaters
Single zone
programming cassette
RX9911, RX9912 and
RX9913
Pilot wire
(RX9911)
Mains borne
signalling
(RX9912)
(RX9913)
Allows multiple panel heaters to be controlled on a common time programme, with slave heaters linked to a master
via pilot wires or mains borne signalling.
Master/slave control – master heater fitted with programmer controls up to 20 slave heaters
(RX9913 receivers required for MBS versions)
Choice of 7 preset or 1 customisable programme per day of the week, switching heater between comfort and setback modes
(note: not on/off)
Cassette can be removed from heater for easy programming
Programmes saved in memory for 4 hours in event of power failure
Quick start user guides printed on rear of programming cassette
RX9911/RX9912 –
RPX and Apollo
RX9913 –
Monterey, Girona,
Saletto, EPX, RPX
and Apollo
Multizone control
from a wall mounted
programmer
4 zone wall mounted
programmers
RXPW4 and
RXMBS4
Pilot wire
(RXPW4)
Mains borne
signalling
(RXMBS4)
Provides the flexibility of complete system control from the convenience of a single point. Each zone can be
individually configured with a custom 7 day time programme.
Wall mounted, mains powered units
Installer configurable option to allow switching between comfort/setback modes, comfort/off modes or comfort/frost
protection modes
Manual programme override facility, with automatic return to programme at next timed change
Continuous comfort, setback, frost protection and off modes*
Holiday (time absence) mode Easy to install and configure
RXPW4 pilot wire programmer can be used with RXPWIF interface unit to control ancillary appliances, such as towel rails
or hot water systems
Note: For mains borne signalling option, RX9913 receiver cassettes are required for each panel heater or RX03002 for each DuoHeat radiator.
An RXMBSF mains filter is also required.
Note: Pilot wire installations are appropriate for single phase connection only.
* Off mode not applicable for DuoHeat.
Monterey, Girona,
Saletto, EPX, RPX,
Apollo and
DuoHeat radiator
Running a towel rail
or water cylinder
from a wall mounted
control
Pilot wire interface
RXPWIF
Pilot wire Provides additional system versatility by allowing ancillary appliances, such as towel rails or water heaters, to be
controlled via a pilot wire programmer (typically RXPW4 4 zone controller).
Allows control over ancillary appliances up to 3kW (16A) load (typically towel rail or hot water cylinder immersion heater)
Installed local to the appliance being controlled. 38mm single gang wiring accessory back box required (not supplied)
Switches power to appliance when programmer in comfort mode; disconnects supply when programmer in all other modes
Ideal for use with RXPW4 4 zone pilot wire programmer
Towel rails and
hot water immersion
heater cylinder
rated up to
3kW (16A) load
scan for more info
This range of controllers provides
fully programmable energy saving
control for Dimplex electronic
panel heaters, DuoHeat radiators
and now even additional ancillary
appliances, such as towel rails
or hot water systems, providing
unmatched levels of versatility
and energy efficiency.
With options ranging from
24 hour digital timers for individual
heaters, through to single or
4 zone multi heater programmers,
there is a flexible and easy to
use control solution available
to meet the needs of virtually
any application.
Choose the functionality you
require from the first column,
then check that this unit fits your
product and specification needs.
See page 51 for towel rail and
radio frequency controllers.
dimplex.co.uk/controls
Electronic panel heater controls
ENERGY SAVING
32
Electronic panel heater controls
Vista de página 31