Dimplex Heatbook
Technical information
Colour
White.
Installation
Two upper keyhole slots are
provided together with a third
fixing hole to secure the heater
to the wall. The heaters are
supplied without cable.
IP rating
FX models: IPX2. Product should
be mounted at a minimum height
of 600mm if installed in zone 3 of
a location containing a bath or
shower (BS7671: 2001 section 601).
FXIPX4 models: Splashproof IPX4
for bathroom use.
Electrical
All installations must be in accordance
with current IEE wiring regulations.
Construction
Double insulated plastic case.
Moulded in flame retardant self
extinguishing grade nylon.
Safety protection
Manually resettable thermal overload
cut-out and thermal fuselink provide
double protection against overheating
for any reason.
DOWN FLOW FAN HEATERS
FX main dimensions (mm)
FXIPX4 main dimensions (mm)
HB13-D0043
250
min
229
242
Front Side
Shelf
109
280
min
1800
min
High Level Models FX20V
FX20VE
Low Level Models FX20VL
600
min
600
min
Front Side
Shelf
250
min 250
267
131
280
min
1800
min
600
min
HB13-D0044
Model Loading Height Width Depth Weight
FX20V 2.0kW 242mm 229mm 109mm 1.1kg
FX20VE 2.0kW 242mm 229mm 109mm 1.1kg
FX20VL 2.0kW 242mm 229mm 109mm 1.1kg
Model Loading Height Width Depth Weight
FX20IPX4 2.0kW 267mm 250mm 131mm 1.4kg
FX20EIPX4 2.0kW 267mm 250mm 131mm 1.4kg
Model FX20V