
Dimplex Heatbook
Technical information
Construction/Finish
Corrosion resistant body with durable
finish colour matched to the CAB and
DAB air curtain. Finned/sheathed
heating elements with rigid steel
outlet grille vanes to direct airflow.
Colour: White casing with black grille.
Controls
No onboard controls.
All CFH models are controlled via
the additional CFCH controller.
Safety
Manual reset cut-out.
Air temperature rise from
CFH models
Heater dimensions
Installation options – system design
INDUSTRIAL FAN HEATERS
15º30º 45º
CFH120
CFH90
CFH60
900m
3
/h
900m
3
/h
900m
3
/h
A
C
D
Installed range – electronic units
Model Output Supply Airflow Throw Noise level Air-off temp* Height A Width B Depth C Max depth D Weight
CFH60 6kW
220-240V~1PN
380-415V~3PN
900m
3
/h 10m 55dB(A) 40°C 360mm 386mm 565mm 630mm 13.5kg
CFH90 9kW
220-240V~1PN
380-415V~3PN
900m
3
/h 10m 60dB(A) 55°C 360mm 386mm 565mm 630mm 14.5kg
CFH120
12kW
220-240V~1PN
380-415V~3PN
900m
3
/h 10m 60dB(A) 65°C 360mm 386mm 565mm 630mm 14.5kg
*Calculated at 21°C.
By grouping units together a large output can be gained in a single area.
By spacing units throughout the building, a centrally controlled heating system is possible.
77
The CFH range
Comentários a estes Manuais