1 Introduction
Thank you for choosing a Dimplex Heat Pump. The
Dimplex A-Class heat pump provides outstanding
performance to maximise year-round efficiency,
regardless of the weather conditions. It can deliver
high output and high temperatures even at low
outside air temperatures of -7°C. The sophisticated
controller makes the system easy to use and there
are many more technological innovations including a
scroll compressor that uses enhanced vapour
injection.
2 Scope of delivery
Please ensure you check the scope of delivery before
signing any delivery documentation. Below is a
guideline checklist for what should be contained in
each pack. Claims for missing or damaged parts after
signing for the delivery will not be accepted.
There are 3 options to select from when installing a
Dimplex Heat Pump:
Pack 1 - Space heating and Dimplex A-
Class Cylinder
This pack should contain four boxes;
Heat Pump
ACCHYPK Hydraulics Kit A
Cylinder
Cylinder Accessories
A separate wiring centre is not required as the
wiring centre is built into the cylinder.
The ACCHYPK hydraulics kit A contains all of the
necessary hydraulic components.
Pack 2 - Space heating and Dimplex
Standard Heat Pump Cylinder
This pack should contain five boxes;
Heat Pump
ACCHYPK Hydraulics Kit A
Cylinder
Cylinder Accessories
Wiring Centre
A separate wiring centre is required as the
wiring centre is not built into the standard
cylinder.
The ACCHYPK hydraulics kit A contains all of the
necessary hydraulic components.
Pack 3 Space heating only
This pack should contain three boxes;
Heat Pump
ACCHYPK Hydraulics Kit A
Wiring Centre
Accessories
A separate wiring centre is required to wire the
circulation pumps and controls.
The ACSHYPK hydraulics kit B contains all of the
necessary hydraulic components.
Details of all packs/components provided are shown
on pages v-vii of this manual.
3 Pre-Installation Advice
3.1 Warnings
3.1.1 Handling and Transport
When transporting, moving and installing the heat
pump, ensure that it is not tilted by more than 45°
(in any direction), for any prolonged period of
time.
Do not attempt to lift the heat pump manually, as
it weighs 130kg and should only be lifted using the
appropriate lifting devices.
Ensure that there is a clear pathway for a truck to
deliver the heat pump as close to the selected
location as possible.
The installer must use a suitable lifting method, in
accordance with health and safety regulations.
Straps must also be used with the lifting rod to
prevent the heat pump from toppling.
!
Figure 3: Handling of heat pump
Figure 2: Allowable tilt angle during handling
Tilt Angle
Max. 45°
Max. 45°