A-Class Air Source Heat Pump
A12M / A16M: Installation Manual
8/60472/0
Issue 1.03
IMPORTANT THIS MANUAL MUST BE LEFT WITH THE USER AFTER INSTALLATION, INCLUDING THE
HAND-OVER FORM AT THE BACK, WHERE THE INSTALLER SHOULD RECORD KEY INFORMATION
DURING COMMISSIONING.
Vista de página 0
1 2 3 4 5 6 ... 39 40

Resumo do Conteúdo

Página 1 - Issue 1.03

A-Class Air Source Heat Pump A12M / A16M: Installation Manual 8/60472/0 Issue 1.03 IMPORTANT – THIS MANUAL MUST BE LEFT WITH THE USER AFTER INSTALLAT

Página 2 - Overall View

3 3.4 Heat Pump Sizing  Ensure that the correct size heat pump has been selected in accordance with the latest version of MIS3005 (f

Página 3 - Contents

4 Figure 6(b): Label Figure 6(a): Plumbing with isolation valve with strainer to be fitted to return pipe  Heat pump 

Página 4

5 Space Heating Only DHW with A-Class Cylinder Water Flow Rate @ 2100 l/h (nominal) @ 1800 l/h (typical) Associated Head Available 14 kPa

Página 5 - Pack 1:

6 4 Installation 4.1 Plumbing  The system must be filled and flushed with clean fresh water to ensure the removal of all the air from the install

Página 6 - Pack 2:

7 Figure 8 (a): Wiring configuration of space heating and hot water - Dimplex A-Class cylinder MODBUS Cable User Interface D I 0 1 D I 0 2D I 0 3D

Página 7 - SPACE HEATING ONLY

8 Figure 8 (b): Wiring configuration of space heating and hot water – Dimplex standard heat pump cylinder User Interface MODBUS Cable N T C — D H W

Página 8 - Max. 45°

9 Figure 8 (c): Wiring configuration of space heating only User Interface N T C — D H W NTC-Zone 1 NTC-Zone 2 NTC-Zone 3 NTC-Zone 4 D I 0 1 D

Página 9

10 Figure 9: Opening the casing to fit electrical connections Figure 10: Heat pump electrical connections NOTE: Please ensur

Página 10

11 4.3.1 Heat pump electrical connection To make electrical connections to the heat pump:  Feed power cable and controller cable through gla

Página 11 - Figure 6(b): Label

12 Figure 16: User interface (UI) User Interface (Jumper ON) Wiring Centre (Jumper OFF) Heat Pump (Jumper ON) MODBUS cable Figure 11: Recommended MOD

Página 12 - sized to meet the

ii Overall View Figure 1(a): Outer dimensions of heat pump Figure 1(b): Position of heat pump name plate and connections Figure 1 (c) : Internal

Página 13

13 Figure 19(a): Initial Installer Menu screen Figure 17: Home Screen INFORMATION MENU 6 Getting Started When switching on the heat pu

Página 14 - User Interface

14 Figure 22: Temperature Control screen Figure 23: Waterside Check screen Figure 19(c): Installer Menu with Commissioning option after Language Se

Página 15 - Dimplex Standard

15 Figure 26: Electrical Connections screen NOTE: If any changes must be made to the commissioning configuration (e.g. selecting a differ

Página 16

16 Figure 27: Water Flow Check NOTE: It is possible to use space heating without completing the DHW setup. This can be done by select

Página 17

17 Figure 33(c): DHW test screen (the test can be postponed or stopped here) Figure 33(b): DHW Test Complete screen NOTE: It is possible to post

Página 18

18 7.7 Heating curves When selecting heating curves, you will do so zone by zone. Selecting the zone and pressing ‘Next’ will allow you to select

Página 19

19 NOTE: If the same error occurs 10 times or more in succession, the lock out feature on the compressor will be triggered. In order to res

Página 20 - Figure 17: Home Screen

20 10 System health check/maintenance Heat pump:  Is the fan clear from debris?  Is the tray clear from debris?  Is the condensate drain clear

Página 21

21 11 Technical Specifications – A Class Air-to-Water Heat Pump 1Calculated to EN15316 excluding hot water 2According to EN 12102. 3Fan

Página 22

22 Appendices A Refrigerant cycle

Página 23 - Figure 29: DHW Set-up screen

iii Contents Introduction 1 Scope of Delivery 1 Pre-Installation Advice

Página 24

23 Table B: List of available Schematics for selection during Commissioning No. on UI Code Heating type No. of Zones DHW Schematic diagram 1 1020

Página 25

24 C - Schematics 1, 2, 3 & 4: Space Heating Only

Página 26 - 9 Service Menu

25 D – Schematics 5, 6, 7 & 8: Zone Space Heating & DHW

Página 27

26 E - Schematics 9, 10, 11 & 12: Bivalent Space Heating

Página 28 - ? 11/>0.95 11/>0.95

27 F - Schematics 13, 14, 15 & 16: Bivalent Zone Space Heating & DHW

Página 29 - Appendices

28 G - Wiring centre electrical connections – with A Class cylinder

Página 30

29 H - Wiring centre electrical connections – with non A Class cylinder / no cylinder

Página 31

30 I - Controller cable connections

Página 32

31 J - Installer Menu Flow Chart DHW Setup DHW Test Electrical Connections (DHW) Waterflow Checks Language Selection Commissioning General/Schematic

Página 33

32 Installer Hand-Over Form UK Customer Care Line 0844 879 35 88 Schematic number used for commissioning:Note: this installation manual needs to be

Página 34

iv 7.1 General/Schematic 14 7.2 Waterside Check 14 7.2.2 Temperatur

Página 35

33 EC Declaration of Conformity GDC Group Limited, Millbrook House, Grange Drive, Hedge End, Southampton, Hants, SO302DF, United Kingdom Manuf

Página 36

v SPACE HEATING AND DIMPLEX A-Class CYLINDER A Class Heat pump A12M / A16M Hydraulics Kit A which includes: ACCHYPK User interface (UI) 17546

Página 37

vi SPACE HEATING AND DIMPLEX STANDARD HEAT PUMP CYLINDER A Class Heat pump A12M / A16M Hydraulics Kit A which includes: ACCHYPK User interface

Página 38

vii SPACE HEATING ONLY A Class Heat pump A12M / A16M Hydraulics Kit B which includes: ACSHYPK User interface (UI) 1754600 Pump - UPM GEO 25-8

Página 39 - Installer Hand-Over Form

1 1 Introduction Thank you for choosing a Dimplex Heat Pump. The Dimplex A-Class heat pump provides outstanding performance to maxim

Página 40 - EC Declaration of Conformity

2 3.1.2 General  Installation and any service work on the heat pump may only be performed by authorised and qualified installer and