Start-Up – Function Test
Start-Up
Before switching on the power supply or making a test run, check whether:
1. All electrical connections are present and have been installed properly according to the circuit diagram
(permanent screw connections and plug connections, ground, fuses).
2. The indoor and outdoor units have been installed in a secure and vibration-proof way.
3. The split pipes have been laid correctly, maximum length has not been exceeded, they are fastened with
sufficient torque, their insulation is undamaged and the couplings have been insulated.
4. The search for refrigerant leaks has been carried out with no positive results.
5. All installation residues or dirt have been removed from both parts of the device and any air vents covers
have been removed.
6. The refrigerant shutoff valves (see also Step 8 in the section “Pre-filled refrigerant pipes KMSL…”) on the
outdoor unit have been opened.
7. The air filter and the condensation drainage pipe have been properly installed.
8. Charged batteries of the size specified have been inserted correctly into the remote control.
9. The manual “AUTO/STOP” switch is set to the “RUN” position.
Function test
Connect the device to the power supply and then operate the “ON/OFF” switch of the remote control
the device should now switch on (usually in “AUTO operation” or in the operation mode set previously
using the remote control).
Using the remote control, test all operating modes (cooling, air recirculation, heating, dehumidifying) as
far as ambient temperatures (remember operating limits) will allow. Please note when switching from one
mode of operation to another that certain start-up times or pauses are functionally necessary.
If the device cannot be switched on using the remote control
Switch the “AUTO/STOP“ sliding switch on the indoor unit (first open the air inlet grid) to the AUTO
setting the device should now switch to a mode of operation selected automatically (by the device)
depending on ambient temperature and it should be possible to make other settings using the remote
control. If this is not the case, please contact your after-sales service. The modes of operation can also
be tested in the “TEST” position; if used, this setting should be changed after test operation and the
sliding switch should be set to AUTO. (Permanent operation in the TEST setting leads to malfunctions!)
If the device starts up automatically when switched on and cannot be controlled using the remote
control
Set the AUTO/STOP switch on the indoor unit to “STOP”. The device switches off. Then set the sliding
switch to “AUTO” or “RUN” again. It should now be possible to set the device using the remote control; if
this is not the case, please contact your after-sales service.