Split room air conditioners with rapid
refrigerant coupling
Indoor unit
Outdoor unit
KSS 4504 CB
KSS 4504 C
KSS 4504CI
KSS 4504CA
KSS 6004 CB
KSS 6004 C
KSS 6004CI
KSS 6004CA
Cooling capacity / heat output
1)
kW 4.5 / 5.2 6.0 / 6.5
Air volumes, indoor unit m³/h 700 720
Connection voltage
1/N/PE a230 V
Nominal power consumption for cooling /
heating
kW 1.75/ 1.75 2.30 / 2.30
Sound power level, outdoor / indoor unit
(approx.)
dB(A) 58 / 46 59 / 48
Refrigerant R 407C
Net weight outdoor / indoor unit kg 58 / 12 59 / 12
Dimensions, outdoor unit (W x H x D) mm 950 x 700 x 412 950 x 700 x 412
Dimensions, indoor unit (W x H x D) mm 907 x 290 x 195 907 x 290 x 195
Difference in height between device units,
maximum
m 10
Length of refrigerant pipe, maximum m 20
Temperature range, cooling
Indoor unit (adjustable range) Upper operating limit +30 °C / lower operating limit +16 °C
Outdoor unit (fixed-setpoint conditions) Upper operating limit +43 °C / lower operating limit 0 °C
Temperature range, heating
Indoor unit (adjustable range) Upper operating limit +30 °C / lower operating limit +16 °C
Outdoor unit (fixed-setpoint conditions) Upper operating limit +43 °C / lower operating limit -7 °C
Electrical connection lines
Mains cable (dimension / length) mm² 4 x 2.5 / 5.2 m 4 x 2.5 / 5.2 m
Control line (dimension / length) mm² 5 x 1.0 / 6.8 m 5 x 1.0 / 6.8 m
Energy efficiency class
3)
D D
Coefficients of performance
(cooling/heating)
4)
2.57 / 2.97 2.6 / 2.8
Refrigerant pipe accessories
3)
(essential)
consisting of a suction and pressure pipe, insulated and pre-filled with refrigerant
Pre-filled refrigerant pipe, length 2.5 m
KMSL 3858-2 KMSL 3858-2
Pre-filled refrigerant pipe, length 5.0 m
KMSL 3858-2 KMSL 3858-2
Split room air conditioners for wall mounting
with flanged connections, not for use with KMSL refrigerant pipes
(technical data see above)
Indoor unit KSS 4504C IB KSS 6004C IB
Outdoor unit KSS 4504C AB KSS 6004C AB
Pipe for liquid mm
© 10 x 1 © 10 x 1
Suction gas pipe mm
© 16 x 1 © 16 x 1
Split pipes max. length / max. height m 20 / 10 20 / 10
Special accessories
comprising 2 brackets for wall mounting of outdoor unit
Wall bracket
WKS 357 WKS 357
Condensation pump
KSI 3100 KSI 3100
1) Nominal data acc. to ISO 5151
2) Refrigerant pipes may be joined to extend them. The maximum permitted length of pipe must be observed.
3) In compliance with 92/75/EC, Directive 2002/31/EC
4) Acc. to EN 14511