Dimplex KSS 2504 Instruções de Operação Página 4

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 36
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 3
4
Technical Data
Split room air conditioners with rapid
refrigerant coupling
Indoor unit
Outdoor unit
KSS 2504 AB
KSS 2504 A
KSS 2504AI
KSS 2504AA
KSS 3204 AB
KSS 3204 A
KSS 3204AI
KSS 3204AA
Cooling capacity / heat output
1)
kW 2.5 / 2.8 3.2 / 3.5
Air volume, indoor unit m³/h 420 460
Connection voltage
1/N/PE a230 V
Nominal power consumption for cooling /
heating
kW 0.79 / 0.97 1.09 / 1.24
Sound power level, outdoor / indoor unit
(approx.)
dB(A) 52 / 36 55 / 39
Refrigerant R 410A
Net weight outdoor / indoor unit kg 32 / 8.5 32 / 8.5
Dimensions, outdoor unit (W x H x D) mm 848 x 540 x 260 848 x 540 x 260
Dimensions, indoor unit (W x H x D) mm 770 x 250 x 180 770 x 250 x 180
Difference in height between device units,
maximum
M 10
Length of refrigerant pipe, maximum M 20
Temperature range, cooling
Indoor unit (adjustable range) Upper operating limit +30 °C / lower operating limit + 16 °C
Outdoor unit (fixed-setpoint conditions) Upper operating limit +43 °C / lower operating limit -5 °C
Temperature range, heating
Indoor unit (adjustable range) Upper operating limit +30 °C / lower operating limit +16 °C
Outdoor unit (fixed-setpoint conditions) Upper operating limit +43 °C / lower operating limit -7 °C
Electrical connection lines
Mains cable (dimension / length) mm² 3 x 1.0 / 5.2 m 3 x 1.5 / 5.2 m
Control line (dimension / length) mm² 2 x 0.75 / 6.0 m 2 x 0.75 / 6.0 m
Energy efficiency class
3)
A B
Coefficients of performance (cooling /
heating)
4)
3.2 / 2.9 3.0 / 2.8
Refrigerant pipe accessories
3)
(essential)
consisting of a suction and pressure pipe, insulated and pre-filled with refrigerant
Pre-filled refrigerant pipes, length 2.5 m
KMSL 1438A-2 KMSL 1412A-2
Pre-filled refrigerant pipes, length 5.0 m
KMSL 1438A-5 KMSL 1412A-5
Split room air conditioners for wall mounting
with flanged connections, not for use with KMSL refrigerant pipes
(technical data see above)
Indoor unit KSS 2504A IB KSS 3204A IB
Outdoor unit KSS 2504A AB KSS 3204A AB
Pipe for liquid mm
© 6 x 1 © 6 x 1
Suction gas pipe mm
© 10 x 1 © 12 x 1
Split pipes max. length / max. height m 20 / 10 20 / 10
Special accessories
comprising 2 brackets for wall mounting of outdoor unit
Wall bracket
WKS 357 WKS 357
Condensation pump
KSI 3100 KSI 3100
1) Nominal data acc. to ISO 5151
2) Refrigerant pipes may be joined to extend them. The maximum permitted length of pipe must be observed.
3)
In compliance with 92/75/EC, Directive 2002/31/EC
4) Acc. to EN 14511
Vista de página 3