Installation Notes for Split Air Conditioners
Before choosing a room air conditioner, we recommend carrying out a cooling load calculation according to
the standard, or on the basis of a relevant standard. Forms for cooling load calculation complete with
instructions can be obtained from the manufacturer or wholesaler or in the Internet at www.dimplex.de.
Note: Indoor or outdoor units which are not installed according to instructions may cause a reduction or loss
of warranty in the case of repair.
Choosing the installation location
It is very important to install split devices in suitable locations, as it is difficult, and thus expensive, to move
them after installation. If possible, decide on the installation location in agreement with the final customer.
The installation must be suitable for bearing the weight and the operational vibration of the indoor or outdoor
unit on a permanent basis.
Notes on the installation of the indoor unit
- The circulating air should flow through the whole of the room to be cooled.
- The flow of cold air should not be directed at persons or their place of work.
- The condensation formed during cooling must be drained off without impairing functioning. If
condensation can only be led off upwards or without a downward slope, then the installation of a
condensation pump is necessary.
- The unit may not be installed in rooms subject to high humidity in which the device is in contact with
moisture or water.
- The device may not be installed in rooms in which oil vapour is emitted or could be emitted.
Notes on the installation of the outdoor unit
- The outdoor unit should be installed in a place where it will not become soiled.
- When there is a danger of condensation freezing (heating operation when outside temperatures are low),
the condensate drain stubs should be removed and additional insulation be provided for the drainage
area. Freezing condensation (e.g. the formation of ice on the heat exchanger) can impede the fan
function of the outdoor unit.
- The outdoor unit must be installed in compliance with the regulations regarding the assessment of
operational noise in the neighbourhood. In particular, a suitable distance from bedrooms and similar
rooms should be maintained.
- The device may not be installed in areas of aggressive air!
Scope of supply
Please check that the delivery is complete and that the devices are undamaged.
The scope of supply includes:
1. Split air conditioner consisting of an indoor and an outdoor unit (two VPE - for a complete order)
2. Mounting plate for wall mounting of the indoor unit, slotted into it (incl. screws)
3. Remote control (incl. 2 batteries)
4. Condensation drain plug for draining condensation in the outdoor unit
5. Assembly and operating instructions
6. Length of insulating tube (approx. 250 mm x diam.
i
20 mm)
7. Control line with connection plug and a connection cable to the power supply (see Technical Data)
8. Sealant (in box – for sealing the wall around the pipes)