PowerFlex 700L Technical Data
44 Publication 20L-TD001A
Recommended Cooling Loops
Liquid-to-Liquid Heat Exchanger Selection
Estimated Amount of Coolant for the Drive Loop
Hose Kits
Recommended Chillers (from Dimplex Thermal Solutions)
Chiller Specifications
For chiller pricing/ordering, contact Dimplex Thermal Solutions:
USA and Canada: 1-800-968-5665
Elsewhere: 1-269-349-6800
Drive Frame Size
Supply Loop Requirements
(1)
(1)
Supply loop requirements are for the input to the heat exchanger. These are not requirements for the drive. The output of the heat exchanger is designed to meet the flow and
pressure requirements of the drive. For the flow and pressure requirements of the drive, see the table on page 46
.
Liquid-to-Liquid Heat
Exchanger Cat. No.
(3)
(3)
Recommended cooling loops shown are based on a single drive per cooling loop. Consult the factory for use of multiple drives on one cooling loop.
Minimum Flow @ Pressure
(2)
(2)
The minimum pressure applies to the pressure drop across the heat exchanger and does not take into account additional pressure drop in the system such as piping or hosing.
Maximum Pressure Temperature Range
2 15.1 LPM @ 0.83 bar (4 GPM @ 12 PSI) 8.62 bar (125 PSI) 0-40°C (32-104°F) 20L-LL13K-P75A
3A 22.7 LPM @ 0.83 bar (6 GPM @ 12 PSI) 8.62 bar (125 PSI) 0-35°C (32-95°F) 20L-LL13K-P75A
3B 56.8 LPM @ 0.83 bar (15 GPM @ 12 PSI) 8.62 bar (125 PSi) 0-35°C (32-95°F) 20L-LL24K-1P0A
Drive Frame Size Estimated Amount of Coolant
(1)
(1)
The estimated amount of coolant is based on the heat exchanger using 1.2 m
(4 ft.) hoses. Longer hoses require more coolant. The maximum hose length
of 9.1 m (30 ft.) would require up to an additional 2.8 liters (3/4 gal.).
2 15.1 liters (4 gal.)
3A 19 liters (5 gal.)
3B 19 liters (5 gal.)
Hose Length
Hoses
per Kit
Drive Side
(1)
Coupling Size
(1)
All drive side hose kit fittings are 37 degree flare.
Heat Exchanger Side
Coupling Size Used With Hose Kit
(2)
Cat. No.
(2)
Each hose kit contains two (2) hoses and the appropriate connectors.
When a chiller or liquid-to-air heat exchanger is preferred, we recommend consulting with a cooling
loop supplier such as Dimplex Thermal Solutions. The following are recommended chillers.
3 m (10 ft.) 2 0.75 inch 0.75 inch Frame 2 and 13 kW heat exchanger 20L-GH10-B1
9.1 m (30 ft.) 2 0.75 inch 0.75 inch Frame 2 and 13 kW heat exchanger 20L-GH30-B1
3 m (10 ft.) 2 1 inch 1 inch with 90° elbow Frame 3A and 13 kW heat exchanger 20L-GH10-A2
9.1 m (30 ft.) 2 1 inch 1 inch with 90° elbow Frame 3A and 13 kW heat exchanger 20L-GH30-A2
3 m (10 ft.) 2 1 inch 1 inch Frame 3B and 24 kW heat exchanger 20L-GH10-A1
9.1 m (30 ft.) 2 1 inch 1 inch Frame 3B and 24 kW heat exchanger 20L-GH30-A1
Drive Frame Size Capacity Flow Rate Pressure Reservoir Size Piping (Inlet and Outlet) Chiller Model
(1)
(1)
Each chiller is designed for single drive cooling for indoor installation only. For applications requiring multiple drives using one chiller or outdoor use, contact Dimplex Thermal Solutions.
2 and 3A 16,983 watts 94.6 LPM (25 GPM) 3.44 bar (50 PSI) 117.3 L (31 gal) 1-1/4 in. NPT KV5000
3B 28,110 watts 151.4 LPM (40 GPM) 3.44 bar (50 PSI) 181.7 L (48 gal) 1-1/4 in. NPT KV7500
Chiller Model Electrical Line Input
(1)
(1)
Desired Line Voltage must be specified upon ordering.
Rated Load Dimensions Weight
KV5000 230V, 3 phase, 60 Hz 29 Amp 1067 mm L x 711 mm W x 1676 mm H
(42 in. L x 28 in. W x 66 in. H)
249.5 kg
(550 lbs.)
460V, 3 phase, 60 Hz 17 Amp
KV7500 230V, 3 phase, 60 Hz 40 Amp 1270 mm L x 914 mm W x 1676 mm H
(50 in. L x 36 in. W x 66 in. H)
340 kg
(750 lbs.)
460V, 3 phase, 60 Hz 22 Amp