PowerFlex 700L Technical Data
8 Publication 20L-TD001A
Standard Drive Product Selection
400V AC Three-Phase Drives
480V AC Three-Phase Drives
600V AC Three-Phase Drives
690V AC Three-Phase Drives
Output Amps (with 400V AC Induction Motor)
(1)
(1)
Frame 2 ratings are based on 50°C ambient and 50°C coolant. Frame 3A and 3B ratings are based on 40°C ambient and 40°C coolant.
Nominal Power Ratings IP20, NEMA/UL Type 1
(2)
(2)
Frames 3A and 3B only. Frame 2 drives are IP00, NEMA/UL Type Open.
Frame
Size
PWM
Freq.
(kHz)
Normal Duty Heavy Duty Normal Duty Heavy Duty
Catalog No.
Cont.
110%
1 Min.
150%
3 sec.
Cont.
150%
1 Min.
200%
3 sec.
kW HP kW HP
360 396 540 264 396 540 200 268 150 200 20LC360N0ENNAN10WA 2 4
650 715 975 475 715 975 370 500 270 365 20LC650A0ENNAN10WA 3A 4
1250 1375 1875 915 1375 1875 715 960 525 700 20LC1K2A0ENNAN10WA 3B 4
Output Amps (with 480V AC Induction Motor)
(1)
(1)
Frame 2 ratings are based on 50°C ambient and 50°C coolant. Frame 3A and 3B ratings are based on 40°C ambient and 40°C coolant.
Nominal Power Ratings IP20, NEMA/UL Type 1
(2)
(2)
Frames 3A and 3B only. Frame 2 drives are IP00, NEMA/UL Type Open.
Frame
Size
PWM
Freq.
(kHz)
Normal Duty Heavy Duty Normal Duty Heavy Duty
Catalog No.
Cont.
110%
1 Min.
150%
3 sec.
Cont.
150%
1 Min.
200%
3 sec.
kW HP kW HP
360 396 540 264 396 540 224 300 175 235 20LD360N0ENNAN10WA 2 4
650 715 975 475 715 975 445 600 325 440 20LD650A0ENNAN10WA 3A 4
1250 1375 1875 915 1375 1875 860 1150 630 845 20LD1K2A0ENNAN10WA 3B 4
Output Amps (with 600V AC Induction Motor)
(1)
(1)
Frame 3A and 3B ratings are based on 40°C ambient and 40°C coolant.
Nominal Power Ratings IP20, NEMA/UL Type 1
Frame
Size
PWM
Freq.
(kHz)
Normal Duty Heavy Duty Normal Duty Heavy Duty
Catalog No.
Cont.
110%
1 Min.
150%
3 sec.
Cont.
150%
1 Min.
200%
3 sec.
kW HP kW HP
425 470 640 315 470 640 345 465 255 345 20LE425A0ENNAN10WA 3A 4
800 885 1200 590 885 1200 650 870 480 640 20LE800A0ENNAN10WA 3B 4
1175 1295 1765 860 1295 1765 955 1275 695 935 20LE1K1A0ENNAN10WA 3B 2
(2)
(2)
Must operate at 2 kHz PWM only, and only as a stand-alone inverter module (“K” in catalog string position 13).
Output Amps (with 690V AC Induction Motor)
(1)
(1)
Frame 3A and 3B ratings are based on 40°C ambient and 40°C coolant.
Nominal Power Ratings IP20, NEMA/UL Type 1
Frame
Size
PWM
Freq.
(kHz)
Normal Duty Heavy Duty Normal Duty Heavy Duty
Catalog No.
Cont.
110%
1 Min.
150%
3 sec.
Cont.
150%
1 Min.
200%
3 sec.
kW HP kW HP
380 420 570 280 420 570 355 475 260 350 20LF380A0ENNAN10WA 3A 4
705 780 1060 520 780 1060 657 881 485 650 20LF705A0ENNAN10WA 3B 4
1050 1155 1575 770 1155 1575 980 1315 720 965 20LF1K0A0ENNAN10WA 2
(2)
(2)
Must operate at 2 kHz PWM only, and only as a stand-alone inverter module (“K” in catalog string position 13).