PowerFlex 700L Technical Data
Publication 20L-TD001A 5
Communication Modules
DPI communication modules provide fast and efficient control and/or data exchange over the following interfaces:
DeviceNet
ControlNet
EtherNet/IP
Remote I/O
Serial Communications
Other open control and communication networks
Unsurpassed Capability in Network Communications
PowerFlex drives are fully compatible with the wide variety of Allen-Bradley DPI
communication adapters, offering the
following benefits:
PowerFlex Architecture-Class LCD Human Interface Modules
An LCD Human Interface Module (also used with the PowerFlex 70, PowerFlex 700, PowerFlex 700S, and PowerFlex
700H) provides multilingual text for startup, metering, programming, and troubleshooting.
Large and easy to read 7 line x 21 character backlit display
Alternate function keys for shortcuts to common tasks
“Calculator-like” number pad for fast and easy data entry (Full Numeric version only)
Control keys for local start, stop, speed, and direction
Remote versions for panel mount applications
PC-based Configuration Tools
DriveExplorer
and DriveExplorer Lite. Simple and flexible “On-line” tools for monitoring and configuring while
connected to a drive.
DriveTools
SP. A suite of software tools which provide an intuitive means for programming, troubleshooting, and
maintaining Allen-Bradley AC and DC drives.
BACnet
®
DeviceNet
ControlNet
EtherNet/IP
Remote I/O
RS485 DF1
PROFIBUS DP
Interbus
LonWorks
Modbus RTU
Modbus TCP
Metasys N2
Siemens P1 FLN
Bluetooth
®
Description
✔✔✔ Unconnected Messaging permits other network devices (e.g. PanelView
) to communicate directly to a drive without routing the
communication through the network scanner.
✔✔✔✔ Adapter Routing – Plug PC into one drive and talk to all other Allen-Bradley drives on same network, without being routed through
the network scanner.
✔✔✔✔✔✔✔✔✔✔✔✔✔✔Access to 100% of all parameters over the network.
✔✔ AutoBaud capability makes initial connections less problematic.
Change of State significantly reduces network traffic by configuring control messages to be sent only upon customer defined states.
Very flexible configuration for each node (Example: “reference must change by more than 5%”).
✔✔ Peer Control provides master-slave type control between drives, where one or more slave drives (consumers) can run based on the
status of a master drive (producer), which can also significantly reduce network traffic.
Automatic Device Replacement (ADR) saves significant time and effort when replacing a drive, by allowing the scanner to be
configured to automatically detect a new drive and download the required parameter settings.
✔✔✔✔✔✔✔✔✔✔✔✔✔✔Flexible Fault Configuration – Adapters can be programmed to take fault based actions such as ramp to stop, coast-to-stop, and
hold last state, as well as send user configurable logic control and speed reference values. In addition, different actions can be taken
based on whether the network experienced a serious problem (broken cable, etc.) versus a network idle condition (PLC set to
“Program”).